TitleProduct

Atomic Absorption Spectrophotometer-Atomic Absorption Spectrometer

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Hunan

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-05 20:46

  • Browse the number:

    141

Send an inquiries

Company Profile

TRYTE TECHNOLOGY (HUNAN) DEVELOPMENT CO., LTD.

By certification [File Integrity]

Contact:Mr. Robin(Mr.)  

Email:

Telephone:

Phone:

Area:Hunan

Address:Hunan

Website: http://lab-instrument.kt-water.com/

PRODUCT DETAILS
TR-TCS-7002 Atomic Absorption Spectrometer

Introduction:

Optical suspension system. Superb by design, the instrument stands up to the test of shaking environment and tough
 temperature condition.

Uniquely designed, one system can be configured to have both flame and graphite furnace installed. The switching
 between these 2 takes about a few seconds. AA-7000 is the most compact AAS system in the world.

Titanium atomized system. It takes advantage of the aero-space technology, use titanium atomized system and burner. It is more resist to erosion, oxidation, and high temperature. The design helps increasing the lifetime of the instrument.

1800 lines/mm diffraction grating, to achieve higher resolution and higher energy.

Deuterium-lamp and background deduction technology, to make the result adjusted more accurately.

Alarming system, in order to guarantee the safety of lamps, graphite furnace, and flame, special design was considered at the beginning. so to make an instrument more reliable and safe to use.

Option to our HG-01 hydride generator, to help your analysis on these elements as AS, Pb, Se, Hg etc..

Graphite furnace auto sampler, auto sampler the process of preparation of standard solvents and sample. Repeatability is better than 98%.

Technical Parameters:

Wavelength Range: 190nm~900nm
Wavelength Accuracy: Full Wavelength ≤±0.2nm
Spectrum Bandwidth: 0.1, 0.2, 0.4, 2.0nm
Resolution: Mn 279.5nm, 279.9nm 
Energy at the wave bottom≤3%
Detecting methods: Flame
Lamp: Hollow Cathode lamp
Adjustable current:0~20mA
Deuterium lamp
Adjustable current:0~200mA
Baseline stability: ≤±0.004Abs/30min
Abs Range: 0~4Abs
Benchmark Elements:
Flame: Cu 5mg/l produces 0.75/Abs, 
Sensitivity: ≤±0.04mg/l,
RSD%: ≤3%
Graphite Furnace: Cd ≤0.5×10-12g
RSD%≤ 3%
Power Voltage: 110V/220V, 50Hz AC, 200W
Size: 800×540×480(mm)
Net Weight: 125kg (including flame furnace)

 

TR-7001 Flame/Graphite Furnace AAS (Manual)



Excellent performance / price ratio
Advanced built-in graphite furnace power supply
Can be equipped with a graphite furnace autosampler
Durable graphite tube, can be used for a long time at under 2000 ºC
Maximum 20 segment graphite furnace temperature program
Powerful software that features easy-to-use method parameter setup and advanced calibration curve fitting
Unique background reduction design that allows for accurate analysis of high salinity, high background samples such as soy sauce, food, etc.

 
 
[VARIAN] [PE]